Diagnostic Instruments - DI 2200

The DI 2200 has been withdrawn from our hire list as the instrument can no longer be maintained.
For FFT analysis please see the B&K 2250 FFT version.
The following information is for reference purposes only.
| DI 2200 |
Real Time - FFT Analyser - dual channel |
£ n/a * |
Small battery operated, narrow band, analyser -

DC - 40 kHz in 10 ranges with engineering units and zoom

FFT with up to 1600 lines resolution

1/3 and 1/1 octave band mode.

Memory card and RS-232 output to a serial printer, PC etc.,

Frequency, Time Domain, Transfer Function measurements etc.

BNC connectors for DC or AC coupled voltage inputs, plus direct connection of IEPE accelerometers.

Built-in integration circuits and engineering units for both vibration and noise measurements.
For narrow band noise or pure tone measurements - plug the output of a
sound level meter into this small, portable analyser. Ideal for tracking down pure tones and harmonics that occur in the same 1/3-octave band.
For vibration measurements include one or two
Metra Ks76 accelerometer sets and a
B&K 4294 vibration calibrator .
Alternatively add a
B&K 2635 charge amplifier as a front-end, for use with a variety of accelerometers.
To see our range of accelerometers click
here.
Manufacturer's Specifications
ADT Win download software with PC cable and a mains / charger unit are included. The ADT Win software is not XP compatible.
* Our standard hire charges are based on a 4-day minimum period,
details other options.
Gracey & Associates 01933 624212 hire@gracey.com
British Standards accreditation for noise and vibration instrument hire and calibration