Nor 140


All Nor 140 analysers supplied by Gracey & Associates include options 1, 3, 4 and 6




Option   11/1-octave band filters - real time
Option 1d Option 1c Option 1b Option 1a shim
  • Parallel 1/1-octave band, real time filters, 0.5 Hz - 16 kHz
  • All filters fulfill the IEC 61260 class 1 digital IIR base 10 requirements
  • 120 dB 'one-range' in all filter bands
  • Graphical and numeric display
  • A-weightig [pre-weighting] feature available on displayed results
  • A limited frequency range 8 Hz - 16 kHz can be set in order to avoid low frequency noise and a 3 Hz third order high pass filter is then enabled in the analogue input stage to prevent overload due to low frequency noise.
  • The wide frequency range with full dynamic range of more than 120 dB makes the instrument well suited for both vibration and noise measurements



Option   31/3-octave band filters - real time
Option 3d Option 3c Option 3b Option 3a shim
  • Parallel 1/3-octave band, real time filters, 0.4 Hz - 20 kHz in one span
  • All filters fulfill the IEC 61260 class 1 digital IIR base 10 requirements
  • 120 dB 'one-range' in all filter bands
  • Graphical and numeric display
  • A-weightig [pre-weighting] feature available on displayed results
  • A limited frequency range 6.3 Hz - 20 kHz can be set in order to avoid low frequency noise and a 3 Hz third order high pass filter is then enabled in the analogue input stage to prevent overload due to low frequency noise.
  • The wide frequency range with full dynamic range of more than 120 dB makes the instrument well suited for both vibration and noise measurements



Option   4Calculation of Ln statistical values
Option 4 shim
  • Calculates 7 fixed Ln values L1%, L5%, L10%, L50%, L90%, L95% and L99%
  • Parallel calculation of 1 editable Ln, selectable within the range 0.1% - 99.9%
  • Statistical calculations based on 0.2 dB class widths covering the entire 120 dB dynamic range
  • Parallel statistical calculations on both A and C/Z-weighted networks
  • Statistical values calculated for the individual filter bands as well - if the filter option(s) are installed
  • The statistical distribution calculations employs the F time constant and applies to the spectral weighting networks (A and C or Z) as well as all the individual 1/1- and 1/3-octave filter bands (if applicable).
  • The back-erase feature, which deletes the ten most recent seconds of acquired global data prior to a pause upon resuming, updates the statistics buffers as well to maintain consistency.



Option   6Level versus time measurements
Option 6b Option 6a shim
  • Measures the time 'Profile' (level vs. time) of the noise signal with preset time resolution simultaneously with the overall 'Global' measurement
  • Selection of preset intervals within the 1 second to 99 hours interval range
  • Automatic level versus time storage of LAeq, LAmax, and LCpeak or LZpeak
  • Automatic multi-spectrum storage of Leq and Lmax if option 1 is installed
  • Level versus time measurement continues during a paused Global measurement
  • Markers identify any pause, stop or continuation of a measurement
  • Real-time graphical and numeric display of the level versus time results
  • A pause marker is inserted into the time profile in pause mode
  • An overload marker is inserted if overload occurs