Gracey Home Page

Gracey & Associates Hire

Vibrock V901 Digital Vibration Meters



vibrock v901



V901Single channel - tri-axial vibration recorder £ 25 a day *

Vibrock - single channel, 3-axis vibration analyser for continuous level recording or event monitoring.
  • Delivered with a triaxial PPV - Peak Particle Velocity transducer for simultaneous 3-axis recording.
  • Measurement ranges
     Velocity (PPV) : 0.1 mm/s to 200 mm/s
     Displacement :  0.009 mm to 1.6 mm
     Acceleration :    0.01 g to 20 g.
  • LCD display of current levels updated every 10 second, maximum level during last hour and maximum level during current measurement period.
  • Up to 300 events or several weeks continuous recording may be stored in the non volatile memory and quickly downloaded to a PC.
  • Uses 2 ordinary alkaline D cells which will power the system for up 20 days.

Manufacturer's Specifications


Robust, weatherproof and lightweight - kit includes PC download software with a cable.

Transducer leads 1.2 m long, order extension cables if required.
NEW - Two stage audible alarm with 10 m cable and battery charger available


vibrock v901


V901-2Dual channel - Triaxial vibration recorder with Human Vibration Dose measurement £ 33 a day *

Vibrock - dual channel vibration analyser for continuous level recording or event monitoring and/or recording vibration dose levels.

Delivered with one triaxial PPV - peak velocity transducer and a triaxial VDV transducer **.

  • The PPV transducer covers the following measurement ranges
    Velocity (PPV) : 0.1 mm/s to 200 mm/s
    Displacement :  0.009 mm to 1.6 mm
    Acceleration :    0.01 g to 20 g.
  • LCD display of current levels updated every 10 second, maximum level during last hour and maximum level during current measurement period.
  • Up to 300 events or several weeks continuous recording may be stored in the non volatile memory and quickly downloaded to a PC.
  • Uses 2 ordinary alkaline D cells which will power the system for up 20 days.
VDV - Vibration Dose
When using the VDV transducer to measure vibration dose, the instrument complies with BS 6472 and BS 7482 part 3 with automatic day/night change over. Both 30 second and 1 hour dose levels are recorded and the resultant 16 or 8 hour values calculated in the range 0.025 to 10 m/s- 1.75. You can still record the PPV levels etc., on the other channel.

Manufacturer's Specifications

Robust, weatherproof and lightweight - kit also includes PC download software with a cable.

The transducer leads are 1.2 m long, order extension cables if required.
NEW - Two stage audible alarm with 10 m cable and battery charger available

** If you want to use the second channel for additional PPV type measurements, then add an extra PPV transducer and suitable extension cables

We also hire Windows XP laptops loaded with the Vibrock PC software.


vibrock

* Our standard hire charges are based on a 7-day minimum period. Click here for details and other options.

Gracey and Associates   01933 624212
BSI approved for the hire of noise and vibration instruments
 Home 
 Search 

This page lists Vibrock Seismographs for PPV - peak particle velocity vibration, acceleration and displacement measurements in buildings or piling, demolition, quarry blasting, road traffic, rail and a range of other vibration applications plus VDV vibration dose and whole body vibration measurements.