Vibrock - single channel, 3-axis vibration analyser for continuous level recording or event monitoring.
- Delivered with a triaxial PPV - Peak Particle Velocity transducer for simultaneous 3-axis recording.
- Measurement ranges
Velocity (PPV) : 0.1 mm/s to 200 mm/s
Displacement : 0.009 mm to 1.6 mm
Acceleration : 0.01 g to 20 g.
- LCD display of current levels updated every 10 second, maximum level during last hour and maximum level during current measurement period.
- Up to 300 events or several weeks continuous recording may be stored in the non volatile memory and quickly downloaded to a PC.
- Uses 2 ordinary alkaline D cells which will power the system for up 20 days.
Manufacturer's Specifications
Robust, weatherproof and lightweight - kit includes PC download software with a cable.
Transducer leads 1.2 m long, order extension cables if required.
NEW - Two stage audible alarm with 10 m cable and battery charger available |
Vibrock - dual channel vibration analyser for continuous level recording or event monitoring and/or recording vibration dose levels.
Delivered with one triaxial PPV - peak velocity transducer and a triaxial VDV transducer **.
- The PPV transducer covers the following measurement ranges
Velocity (PPV) : 0.1 mm/s to 200 mm/s
Displacement : 0.009 mm to 1.6 mm
Acceleration : 0.01 g to 20 g. - LCD display of current levels updated every 10 second, maximum level during last hour and maximum level during current measurement period.
- Up to 300 events or several weeks continuous recording may be stored in the non volatile memory and quickly downloaded to a PC.
- Uses 2 ordinary alkaline D cells which will power the system for up 20 days.
VDV - Vibration Dose
When using the VDV transducer to measure vibration dose, the instrument complies with BS 6472 and BS 7482 part 3 with automatic day/night change over. Both 30 second and 1 hour dose levels are recorded and the resultant 16 or 8 hour values calculated in the range 0.025 to 10 m/s- 1.75. You can still record the PPV levels etc., on the other channel.
Manufacturer's Specifications
Robust, weatherproof and lightweight - kit also includes PC download software with a cable.
The transducer leads are 1.2 m long, order extension cables if required.
NEW - Two stage audible alarm with 10 m cable and battery charger available
** If you want to use the second channel for additional PPV type measurements, then add an extra PPV transducer and suitable extension cables
|
We also hire
Windows XP laptops loaded with the Vibrock PC software.
|
* Our standard hire charges are based on a 7-day minimum period. Click here for details and other options. |
| This page lists Vibrock Seismographs for PPV - peak particle velocity vibration, acceleration and displacement measurements in buildings or piling, demolition, quarry blasting, road traffic, rail and a range of other vibration applications plus VDV vibration dose and whole body vibration measurements. |