The information on our main web pages is necessarily brief, so for customers who need more details, we provide

squareInternal links to more details and the full specifications on all main pages
squareA Links Page with quick access to the manufacturers web pages and other useful information sites
squareThis page, where we provide some additional notes on a variety of topics.

They are in Acrobat format so they may be download to your PC and read 'off-line' later. Or if you have broadband you may prefer to open any document and read it now. If you do not have Acrobat on your PC, it is available free from Adobe - see our links page

Gracey & Associates   01933 624212
BSI accreditation for noise and vibration instrument hire and calibration
  Home  
  Hire Notes + FAQ  
  Search  
  Standards  
  Calibration  
  Glossary  

Over 500 pages of information on the hundreds of meters and systems we have available for hire.

hr

B&K 2250 Memory Logging Capacity. 32 KB xls file

Simple MS Excel Spreadsheet that helps with estimating the amount of memory a particular measurement will require.

To download right click here and select 'Save ......'

hr

B&K 2260 Memory Estimator. 91 KB xls file

Simple MS Excel Spreadsheet that helps with estimating the amount of memory a particular measurement will require.

To download right click here and select 'Save ......'

hr

Environmental Noise Assessment - Pure Tones 113 KB pdf file

Most people find noise more annoying if it contains audible tones, so it has been the common practice to add a dB penalty, based on a simple subjective assessment. In 1992 the Germans proposed the DIN 45681 which resulted in ISO 1996-2 and the equivalent BS 7445-2

To read the Norsonic article Quantification of Tonal Penalties in Environmental Noise Assessments which also describes how the Nor 110 and Nor 121 analysers measure the tonal values, click here and select Save or Open.

hr

Measuring Extremely Low Levels412 KB pdf file

Nor 840 shim Sometimes you need to measure sound pressure levels below the inherent noise of even the best sound level meters. Levels below 0 dB may be measured using two microphones, a Nor 1264 preamplifier holder and a Nor 840 real time analyser.

To download the Low Level Measurement Note right click here and select 'Save ......'.

hr

MLS - a revolutionary measurement mode for building acoustics 403 KB pdf file

The Nor 840 with MLS measurement mode is the only practical way to measure high sound insulation in high background noise levels, or in a room where the noise excitation level is insufficient. The BS EN ISO 140 Standards introduced testing over the extended range 50 - 5000 Hz. Due to speaker inefficiency below 100 Hz and the need to measure received sound levels at least 10 dB above the background noise at both ends of the spectra; this can be a problem using traditional techniques. The Nor 840 with MLS solves all these problems

To download the MLS Application Note right click here and select 'Save ......'

hr

MLS - Maximum Length Sequence - a little theory 157 KB pdf file

If you would also like to read the theory behind the MLS technique, written by Ole Herman Bjor, then please download the eight page document by right clicking here and selecting ' Save ......

hr

Nor-Mon - noise nuisance investigation 567 KB pdf file

A self-contained system with a client operated switch for the investigation of noise nuisance complaints. Includes a Nor 116 analyser in a lockable case, with batteries, tripod etc., plus a modified Sony D8 DAT Recorder with a Nor 255 remote control.

When a 'noise event' occurs the resident pushes the start button, the raw noise data is captured with date and time on the tape and the Nor 116 analyser simultaneously records the level v time history and / or statistical analysis - 4 selectable modes

To download the Noise Nuisance Application Note, right click here and select Save or Open

See also the B&K Matron

hr

Planning and Noise - PPG24 268 KB pdf file

Planning policy guidance notes set out the UK Government's policies on different aspects of planning. Local authorities must take their content into account in preparing their development plans. They may be material to decisions on individual planning applications and appeals.

This PPG gives guidance to local authorities in England on the use of their planning powers to minimise the adverse impact of noise and builds on the advice previously contained in DOE Circular 10/73. It: - To download PPG24, right click here

hr

Sound Power Measurements 590 KB pdf file

Nor 116 shim The Nor 116 precision sound level meter fitted with option 8 is suitable for

squareEngineering and Survey measurements of the LwA - A-weighted sound power levels.
squareSound power measurements according to BS EN ISO 3740 and BS EN ISO 3746.
squareCE marking of new products.


To download the Sound Power Application Note, right click here and select Save


hr

Vibration Accelerometers - Piezoelectric - Theory and Application. 113 KB pdf file

This handy booklet outlines the advantages and drawbacks of piezoelectric accelerometers, as well as the design. It also discusses mounting, cabling and other practical considerations.

To download a copy - right click here and select 'Save ......'

hr

Vibration Analysis, using a sound level meter. 21 KB pdf file

Gracey & Associates stock a wide range of vibration analysers. However it's worth remembering that a sound level meter will also measure vibration if the microphone can be replaced with an accelerometer. Many sound level meters are suitable, so we hire adaptors for this purpose. The article also deals with converting the sound level meter dB scale to vibration units.

To download right click here and select 'Save ......'

hr

Vibration Conversion Chart - dB to Engineering Units. 26 KB pdf file

Conversion Chart to read off vibration levels and other engineering units from a sound level meter.

To download right click here and select 'Save ......'

hr

Vibration Nomogram 37 KB pdf file

Although converting from acceleration to velocity and displacement for a sinusoidal level is straight forward - this handy chart can make life much easier. - right click here and select ' Save ......'

hr

Vibrock Software  

Vibrock download software for V901, with USB drivers - right click here and select 'Save ......' (5.6 MB ZIP file)

hr Λ

Gracey & Associates   01933 624212
BSI accreditation for instrument hire and calibration
 Home 
 Search 


speed links - accelerometers l bruel & kjaer l building acoustics l construction and demolition l environmental noise l hand-arm vibration - havs l health and safety at work l larson davis l microphones l noise and vibration at work l noise meters l noise pollution l noise sources l norsonic l seismographs l sound insulation l sound intensity l sound level meters l sound power l standards l vibration l vibration white finger l vibrock l whole body vibration